Sale!

Glin LED Sonic Endo Irrigator (60 Tips): 1 year warranty

Original price was: ₹12,000.00.Current price is: ₹6,280.00.

Pickup from nearby metro station or get it home delivered

Check the list of all pickup points at metro stations

Features

Irrigator Tips 

  • Easy snap-on/snap-off design
  • Color-coded by size
  • Ergonomic, cordless, and battery-operated handpiece
  • The strong, flexible, medical-grade polymer composition

Handpiece/Driver 

  • Contra-angled design for easy access to posterior teeth
  • The 3-speed sonic motor provides options of 4.000, 6.000 and 10.000 cpm

Description

The Sonic Irrigator System is used in endodontic treatment by application of sonic energy. The
Irrigator tips are used in conjunction with the Handpiece/Driver to provide the energy for tip
oscillation and vibration. Evidence-based endodontics has shown that cavitation and acoustic
streaming improve debridement and the disruption of the smear layer and biofilm. Activated fluids
promote deep cleaning and disinfection into lateral canals, fins, webs, and anastomoses. A cleaned
root canal system facilitates 3-D obturation and long-term success.

  • Do not submerge the unit in water
  • Do not autoclave unit
  • The Sonic Irrigator System is only to be used by dental professionals

The Sonic Irrigator System is comprised of the handpiece and Irrigator tips of various sizes
The system functions as intended when the original component parts are used together. With the use of non-original components, serious consequences may result. The original components include the Sonic Irrigator handpiece, the Irrigator tip, and the protective barrier. the reference numbers of the Irrigator tips include: 15/02 (Small)25/04 (Medium), 35/04 (Large)

The handpiece provides 3-speed sonic motor options (High, Medium, Low)

The power settings used are ultimately determined by the procedure to be performed, the clinician’s experience, and the power needed to efficiently complete the clinical task

The Sonic Irrigator handpiece does not require calibration for normal use

Specifications

PRECAUTIONS:

  • The Irrigator tip should be disinfected before use, or contamination of the root canal may result.
  • Proper use of the Sonic Irrigator System is required to prevent harm or hazard to the
    patient
  • Improper handling of the Sonic Irrigator handpiece may result in breaking the distal or
    proximal ends of the rocker arm
  • Irrigator tips and protective barriers are intended for single-patient use only. Cross
    contamination may occur to the patient if tips and barriers are re-used
  • Proper disposal of Irrigator tips and protective barriers & the battery is required in accordance with
    local laws and regulations
  • The handpiece must be repaired as necessary under the direction of the manufacturer
  • Proper disposal of the handpiece when the handpiece is deemed non-functional is
    required in accordance with local laws and regulations
  • Removal of the battery is recommended when the handpiece is not to be used for an
    an extended period of time
  • The handpiece should be stored away from strong electromagnetic equipment as it may
    affect handpiece performance
  • The handpiece should be stored aways from portable and mobile RF communications
    equipment as it affects handpiece performance
  • The handpiece should not be used adjacent to or stacked with other
    equipment. Additionally, it should be checked for normal operating functions on a regular
    basis.
  • All endodontic procedures should be carried out with Sonic Irrigator protective barrier sleeve placed over the handpiece

WARNING:

Consult a Cardiologist before using inpatient Having CIEDs ( Cardiovascular Implantable Electronic
Device) , Implantable Cardiovascular Defibrillators, Biventricular Pacemaker, Implantable Cardiac loop
a recorder as it may cause electromagnetic interference.

Contents

  • 1 x Sonic Irrigator
  • 100 x Protective Sleeves
  • 20 x Sonic Irrigator Tips (Small)
  • 20 x Sonic Irrigator Tips (Medium)
  • 20 x Sonic Irrigator Tips (Large)

Directions For Use

Prepare canal to produce a fully tapered shape
• Fill pulp chamber with NaOCI, EDTA, or other final rinse solution
• Select the Irrigator tip that manually fits loosely within 2 mm of working length
• Place the barrier sleeve over the complete length of the handpiece
• Attach the Irrigator tip over the barrier-protected handpiece. The Irrigator should snap
on firmly, promoting a secure connection with the handpiece
• Place the attached Irrigator tip into the prepared root canal • Depress the ON/OFF switch to activate. Note: Switch defaults to high speed upon
activation. Depress the 3-speed switch to select the medium speed or low speed
• Use a pumping action to move the handpiece/Irrigator in short 2-3mm vertical strokes
• Hydrodynamically agitate the intracanal solution for 30-30 seconds
• Irrigate, then use intracanal suction to eliminate loose debris
• Repeat the above steps for each intracanal irrigant used

Prepare canal to produce a fully tapered shape

  • Place the barrier sleeve over the Driver to protect the entire handpiece
  • Attach the Irrigator over the barrier-protected Driver
  • Place the attached Irrigator tip into the prepared root canal
  • Irrigate, then use intracanal suction to eliminate loose debris
  • Repeat the above steps for each intracanal irrigant used

Warranty

  • Manufacturer/Importer warranty of 1 year as applicable for this product.
  • Service and Warranty are handled by the manufacturer/importer directly for this product
  • Deyo will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer
  • Deyo and the Buyer acknowledge that the Products purchased/used are a subject matter of original Manufacturer/Importer’s warranties only
  • Any or all claims in relation to returns and replacement shall be made to the concerned Manufacturer/Importer only and Deyo may assist the customer in registering a request to get the Product replaced or serviced. 
  • The Buyer acknowledges that the Products once sold will not be exchanged or taken back unless the seal of the package or the Product is intact or not altered in any manner or is not tampered as the case may be.