Specifications
Powder / Liquid Ratio (g/g)3.4 / 1.0
Mixing Time (sec.)25-30″
Working Time (min., sec.)2’00”
Net Setting Time (min., sec.)2’20”
Final Finishing Commencing Time
(37°C, after starting mix) (min., sec.)
6’00”
Contents
Gc Gold Label 9 Extra 1-1 Pkg
- 1 x 15 g Powder
- 1 x 8 g Liquid
Gc Gold Label 9 1-1 Pkg:
- 1 x 15 g Powder
- 1 x 8 g Liquid
Gc Gold Label 9 Extra 1-1 Mini Pack:
- 1 x 5g Powder
- 1 x 3 g Liquid
Gc Gold Label 9 1-1 Mini Pack:
- 1 x 5 g Powder
- 1 x 3 g Liquid
Directions For Use
1. POWDER AND LIQUID DISPENSING
- The standard powder to liquid ratio is 3.4g/ 1.0g. (1 level scoop of powder to 1 drop of liquid).
- For accurate dispensing of powder, lightly tap the bottle against the hand. Do not shake or invert.
- To dispense the correct amount of liquid from the bottle turn the bottle upside down, keep the nozzle away from the mixing pad and gently press the bottle. Discard the first 1-2 drops after opening a new bottle as the dispensed amount may not be accurate.
- Close bottles tightly immediately after use.
2. MIXING
- Dispense powder and liquid onto the pad. Using the plastic spatula, divide the powder into 2 equal parts. Mix the first portion with all the liquid for 10 seconds. Incorporate the remaining portion and mix the whole thoroughly for 15-20 seconds (Fig. 1).

3. RESTORATIVE TECHNIQUE
- Prepare the tooth using standard techniques. Extensive mechanical retention is not necessary. For pulp capping, use calcium hydroxide.
- Apply GC CAVITY CONDITIONER (10 seconds) or GC DENTIN CONDITIONER (20 seconds) to the bonding surfaces using a cotton pellet or sponge (Fig. 2).

- Refer to the respective instructions for use.
- Rinse thoroughly with water. Dry by blotting with a cotton pellet or gently blowing with an air syringe. DO NOT DESICCATE. Best results are obtained when prepared surfaces appear moist (glistening) (Fig. 3).

- Mix the required amount of GC Gold Label IX GP-EXTRA. Working time is 2 minutes from the start of mixing at 23°C (73.4°F). Higher temperatures will shorten working time.
- Transfer cement to the preparation using a syringe or other suitable instrument. Avoid air bubbles.
- Form the preliminary contour and cover with a matrix if required (Fig. 4). g) When set, immediately apply GC Fuji VARNISH (blow dry) or GC Fuji COAT LC (light cure for 10 sec.).

4. FINISHING
- Final finishing under water spray using standard techniques can begin at 6 minutes after starting the mix.
- Apply a final coat of G-COAT PLUS and light cure for 20 sec. (Fig.5, 6). Alternatively, apply GC Fuji VARNISH (blow dry) or GC Fuji COAT LC (light cure for 10 sec.)
Instruct the patient not to apply pressure for 1 hour.